Restoring the Last State After a Mains Outage: Controller Memory
- 2026-11-26 18:03
- /
- Alan
After a mains outage the whole entry or room comes back to a state chosen by the system: last scene, a safe default, or off. The restore rule should be set deliberately rather than left to whatever the controller happens to do.
A blackout or a switched-off feed leaves a lighting system to re-initialise when power returns. Owners usually notice the restore behaviour on the next visit: the lights wake at full vivid brightness, revert to a neutral level, or stay dark until a command arrives.
Three common restore outcomes
On power return, a controller may bring back the last colour, level or scene, boot to a fixed neutral default, or remain off until commanded. Each outcome suits a different space; the right choice is set on the controller or central system, not left to chance.
A private room can welcome a return to its evening scene; a shared or public entry should come back to a calm, low default rather than a bright or coloured scene.
Entry and arrival spaces
An entry outline that fades on arrival should not wake at full brightness after an outage, nor revert to a colour scene that signals occupancy when the space is empty. Set its restore state to off or a low neutral level, so the sensor sequence starts from a predictable state each time.
Sensor-triggered lights also re-initialise after a cut-out; confirm they do not fire continuously or hold on until a command arrives once power returns.
Coordinating several controllers
- Check each grouped controller follows the same restore rule.
- Confirm sensors and receivers rejoin their groups after the outage.
- Note any unit that reverts to a default different from the rest.
- Verify the whole system returns to a safe state after a test power cut.
Set and record the rule
Test an actual power cut once commissioning is done, and observe how every zone returns. Adjust each controller's restore setting to the chosen rule, and record the configuration with the project.
If a central system manages the lighting, its restore policy usually overrides individual controller memory; check the system-level setting before assuming a single controller can hold its own state.
Installation Checklist
- Confirm the strip voltage, per-metre load and total run length before sizing the supply or controller.
- Check the mounting position for moisture, heat, clearance and any obstruction before fixing the run.
- Test the sensor, receiver or controller in the finished position, with doors and panels closed.
- Keep drivers, joints and receivers reachable so the run can be serviced without reopening the finish.
Recommended Products
For this detail, the following Arraystarled products are listed in our current catalogue and can be matched to the run after the supply, enclosure and control requirements are confirmed:
- 433MHz Wireless Dimmable Remote Control System (Remote + Receiver)
- 433MHz Wireless Dimming Control System (Remote + Knob + Receiver)
- RF Synchronous 7CH LED Dimmer Controller (Receiver Unit)
Wireless dimmers, remotes and controllers in the range hold scene settings; set the power-restore rule to match whether the space is private, shared or an entryway.
Talk to our application team with your strip length, voltage and ambient condition; we will match the supply, controller or sensor to the actual run rather than a generic rule.