Hiding a Driver and Receiver in a Toe-Kick or Hollow Cabinet Leg
- 2026-11-26 18:02
- /
- Alan
A shallow plinth or hollow cabinet leg can conceal the supply and receiver, but only if clearance, ventilation and signal reach are planned before the furniture goes in.
Under-cabinet and wardrobe lighting often needs the driver and wireless receiver hidden out of sight. The natural spots are the toe-kick cavity, a hollow leg, or a shelf end, but each has limits on depth, heat and radio range.
Clearance for the driver
A driver generates heat and needs air around its case. A toe-kick cavity that is only a few centimetres deep can house the driver only if the case fits with a small margin and the cavity is not sealed shut. Measure the driver depth against the plinth before ordering.
Do not pack the driver into a closed hollow leg with cable stuffed around it. Heat trapped in an enclosed space runs the supply hot and shortens its life. Leave a gap above and beside the case for convection.
Service access
The concealed position must be reachable without removing the cabinet. A removable plinth panel or an access hatch lets the driver and receiver be unplugged and replaced without opening up the joinery.
Bring the feed and strip leads to the driver with enough tail to pull the unit out; a service loop inside the cavity avoids tension on the terminals. Record where the access panel sits so a future service call does not start by guessing.
Receiver and antenna placement
A wireless receiver or 2.4G/RF control unit loses range behind metal, dense timber and the driver itself. Keep the receiver antenna away from the driver case and metal rails, and do not bury the receiver deep inside a fully enclosed metal cabinet.
If the sensor or remote sits on the opposite side of a large cupboard, test pairing and range with the doors open and closed before the installation is finished. A receiver that pairs on the bench may fail behind a closed door.
Routing the cables
- Keep the mains feed and the SELV strip cable separated inside the cavity.
- Anchor the feed cable so its weight does not pull on the driver terminals.
- Leave a short service loop at every joint.
- Plan the hidden position before the cabinets are installed; retrofitting a cavity later means cutting into the joinery.
Installation Checklist
- Confirm the strip voltage, per-metre load and total run length before sizing the supply or controller.
- Check the mounting position for moisture, heat, clearance and any obstruction before fixing the run.
- Test the sensor, receiver or controller in the finished position, with doors and panels closed.
- Keep drivers, joints and receivers reachable so the run can be serviced without reopening the finish.
Recommended Products
For this detail, the following Arraystarled products are listed in our current catalogue and can be matched to the run after the supply, enclosure and control requirements are confirmed:
- RF Synchronous 7CH LED Dimmer Controller (Receiver Unit)
- Wireless LED Receiver / Dimming Controller (Receiver Unit)
- 2.4G Wireless Rotary Dimmer Controller
Wireless receiver and dimming units in the control range suit concealed mounting; keep the antenna clear of metal and the driver so the signal reaches the remote or sensor.
Talk to our application team with your strip length, voltage and ambient condition; we will match the supply, controller or sensor to the actual run rather than a generic rule.