48V Neon End Caps: Local Overheating and the Colour Shift It Causes
- 2026-11-23 16:40
- /
- Alan
At 48V the current is half of 24V for the same wattage, which makes people relax about joints. The end cap still carries every milliamp of that section, and it is the smallest contact area in the run.
A bar frontage used 48V neon in 2 m sections, joined end to end. One section ran warm at the cap and looked slightly greener than its neighbours. The strip was not faulty; the cap contact was.
Why the cap is the weak point
The cap contains the solder or crimp connection between the strip's internal bus and the incoming cable. That connection has a small contact area and is enclosed, so heat has nowhere to go except into the cap body and the extrusion end.
At 48V, a 2 m section at 12 W/m draws 0.5 A. A contact resistance of 0.5 ohm dissipates only 0.125 W, which sounds trivial until you realise it is concentrated in a few square millimetres with no convection.
What you see and measure
- The cap is warmer than the extrusion 200 mm away — often 8–15°C.
- The first 100–200 mm of the section is slightly dimmer or shifted in colour.
- Insulation resistance at the cap may still pass; the fault is resistive, not a short.
- Under thermal cycling the shift becomes more pronounced over months.
Colour shift at the end of a white run is often read as binning. If it is localized to the first 200 mm and follows a warm cap, it is voltage, not binning.
Fixes
Re-terminate the cap with a proper solder joint or a crimped ferrule, then seal. Replace the cap if the contact is corroded. Do not simply tighten the cable gland; that affects sealing, not resistance.
Where sections are joined, use a connector rated for the current and mount it so it is not enclosed in a pocket. A joint in free air runs cooler than one buried in a profile end.
A thermal camera makes this diagnosis quick. Compare the cap temperature with the extrusion 200 mm away after thirty minutes. A cap 10°C hotter is worth re-terminating; a cap 20°C hotter is already degrading the LEDs behind it.
Design note
Long neon runs are often specified in 2 m sections because of shipping and handling. Each joint adds resistance. On a 30 m facade that is 15 joints, and the cumulative loss matters even at 48V.
Feeding every second section from a parallel feeder reduces the current per joint and the heat at each cap. It costs a little cable and removes a maintenance pattern. On a 30 m frontage it also makes fault finding easier, because a dead section can be isolated without opening the whole run.
Our 48V neon ranges list section lengths and current per metre, and the connector range gives the current rating needed at each joint.