Aluminum Channel as a Heatsink at 14.4 W/m: What It Can and Cannot Do
- 2026-11-23 16:35
- /
- Alan
"Use aluminum" is not a thermal design. A 12 mm channel with poor contact can run hotter than a 20 mm channel with proper tape and airflow. The metal is only half the story.
At 14.4 W/m a 24V strip is dissipating serious heat for a flexible circuit. The FPC is thin, the copper is a few tens of microns, and the LEDs are small. Without a path for that heat, junction temperature climbs and output and life fall with it.
What the channel actually does
It spreads heat along the run and adds surface area to convect it away. The limiting factor is usually the contact between the strip and the channel, not the channel's size. A pressure-sensitive adhesive tape is a poor thermal conductor; a thermal pad is much better.
Mass helps with spreading but does not replace surface area. A heavy, enclosed profile with no airflow can hold heat as effectively as it spreads it.
Numbers from a test run
We ran 14.4 W/m white COB on three mounting conditions at 25°C ambient, measuring the channel surface after 60 minutes:
| Mounting | Channel temp | Note |
|---|---|---|
| Bare strip, no channel | 58°C | Free air, adhesive back |
| 16 mm channel, standard tape | 47°C | Open top, still air |
| 16 mm channel, thermal pad | 41°C | Open top, still air |
| 16 mm channel, diffuser fitted | 50°C | Diffuser traps air |
The diffuser figure surprises people. A closed profile looks better and protects the strip, but it also reduces convection. That is acceptable if the strip has thermal headroom; it is not acceptable at the top of the strip's rating.
Choosing a profile for the load
- Under 10 W/m: a 12–16 mm open channel is usually enough with good contact.
- 10–15 W/m: 16–20 mm channel, thermal pad, and some airflow or venting.
- Above 15 W/m: consider a wider profile, a suspended mounting with air on both sides, or lowering the drive current.
- Enclosed coves: add vents or accept a higher operating temperature and derate the strip.
Contact is the cheap win
Replacing standard tape with a 1 mm thermal pad often buys 5–7°C for a few dollars per metre. Cleaning the channel before application matters as much; dust and oil under the tape add resistance, and a pad applied over a dirty surface performs like tape.
Do not rely on the channel alone to fix a thermal problem caused by an enclosed void. If the air around the profile is at 45°C, the best channel in the world is still working against a 45°C sink. Ventilation and derating solve more than extra aluminum does, and they cost less than a wider profile and are easier to reverse.
Our aluminum profile range lists dimensions and thermal recommendations, and the high-output COB ranges state the W/m figures these profiles are sized for.