Dimming to One Percent: When Voltage Drop Becomes Visible
- 2026-11-23 16:32
- /
- Alan
Clients notice uniformity at night, not at noon. The dim scene is the one they live with, and it is where a marginal voltage drop turns into a visible line on the wall.
On a hotel lobby cove we commissioned at 100% and signed off. The first evening the scene dropped to 5% for the bar area, and the last 6 m of the run went visibly pink while the rest stayed neutral. At full output the difference was invisible.
Why low dimming exaggerates differences
LEDs have a threshold voltage below which they barely conduct. Near that knee, a small change in applied voltage produces a large change in current and colour. A strip segment sitting 0.8V lower than its neighbour may look 5% dimmer at full output and 30% dimmer at 3% output.
PWM dimming helps because the LED current is either on or off; the average is set by duty cycle. But the on-state current still depends on the supply voltage, so the voltage drop is still there. Analogue dimming is more sensitive again.
What we measured
At 100%: start 23.6V, end 22.9V. At 5%: start 23.8V, end 23.3V. The absolute difference shrank, but the perceived difference grew, because the far segment was closer to its conduction knee and its colour shifted.
Fixes that work at low dim
- Reduce the electrical length: dual feed, centre feed or injection. This is the only fix that changes the underlying voltage distribution.
- Use a driver with a stable output across the dimming range, not one whose voltage sags at low duty.
- Match strip batches across the run; a colour bin difference that is invisible at full output can dominate at 3%.
- Set the minimum scene above the level where the gradient appears, if the design allows. Many hospitality scenes never need 1%.
What does not work
Raising the driver output to 24.5V lifts everything and makes the near end over-driven. It does not flatten the curve, and it shortens LED life at the top end.
Adding a second dimmer channel per zone is useful for control but does not fix a single long run. Nor does changing the strip batch: if the same segment is dim at every dim level, the cause is electrical, not optical. The strip cannot be the cause when the gradient follows the wiring.
Commissioning at the scenes that matter
Do not sign off at 100%. Walk the space at the lowest scene the client will actually use, at night if possible. Photograph the wall at 5% and 10%. If a gradient appears, fix the feed before the furniture arrives.
For white coves, also check colour at low dim: a warm shift at the tail is a voltage symptom, not a binning problem, if it follows the voltage curve.
Our COB ranges are binned for colour consistency, and the dimming options include protocols that hold a stable low end.