Dual-End Feeding Pitfalls: Mismatched Cable Lengths and Circulating Current
Your Location: Home - Blog

Dual-End Feeding Pitfalls: Mismatched Cable Lengths and Circulating Current

  • 2026-11-23 16:32
  • /
  • Alan

Two feeds into one strip look symmetrical on a sketch. In practice one leg is longer, one joint is tighter, and the strip carries current between them that nobody planned for.

Dual-end feeding is the standard fix for a 30 m run where both ends are accessible. Done properly it flattens the brightness curve. Done casually it creates a new set of problems that only show up under load.

Rule one: the legs must match

If one feed is 6 m of 1.5 mm² and the other is 12 m of 1.0 mm², the shorter leg delivers a higher voltage to its end of the strip. Current then flows through the strip from the stronger feed toward the weaker one, on top of the current the LEDs draw.

That extra current does not disappear. It dissipates in the strip traces, adds heat in the middle of the run, and can make the centre brighter than either end. On a 30 m run with a 1V difference between feeds, the loop current can be several amps before the strip settles.

Match the cable length, the gauge and the connector type. If the physical distance differs, add the difference in cable length deliberately so the electrical paths are the same.

Rule two: one return, one reference

Two separate drivers feeding the same strip is riskier than one driver with two outputs. Each driver regulates independently; small differences in set-point become a continuous current between the two 0V rails. If both are on the same AC circuit and the 0V is bonded, the loop is closed and current flows.

We use one driver with two DC outputs where possible, or two drivers with their 0V bonded at a single point near the strip, never through separate building earth paths. Measure the voltage difference between the two feeds before connecting the second one; if it is more than about 0.2V, stop and find out why.

Rule three: fuse each leg

A dual feed means two paths that can each carry fault current. Fuse or breaker each leg at the driver end. A short in one leg should not back-feed through the other.

How it behaves when done right

On a 30 m 24V COB run at 7 W/m, single-end feed gave 21.2V at the tail. With matched dual feeds, the middle sat at about 23.2V and the ends at 23.6V. The visible gradient was gone, and the strip ran cooler because current per metre was halved near each end.

LayoutEnd voltageMid voltage
Single end21.2 V22.4 V
Matched dual end23.6 V23.2 V

When dual-end feeding is the wrong answer

  • The far end is sealed and cannot be reached without demolition.
  • The strip is addressable and data runs in one direction; a second power feed needs care around data return.
  • The run has a physical break or expansion joint; a single continuous strip between feeds may not exist.
  • The two ends are on different switch legs; feeding both means the strip stays partially energised when one zone is off.

In those cases, mid-run injection or a zone split is usually cleaner. Dual-end feeding is a tool, not a default. Check symmetry, bond the returns, fuse the legs, and measure both feeds before energising. Our COB strip pages give the W/m figures needed to size each leg.

Alan
Alan Linear Lighting Application & Product Technical Specialist, ShenZhen Arraystarled Limited
  • Verifies specifications, installation guides and technical support for SMD/COB LED strips, silicone LED neon flex, flexible wall washers, aluminum profiles, LED drivers and DMX512/WLED control solutions.
  • Compiles internal product specification standards and factory burn-in and lighting test procedures; supports on-site selection, power distribution and commissioning for commercial spaces, exhibitions and architectural outlines.
  • Troubleshoots long-run voltage drop and power injection, power supply load headroom calculations, thermal management and aluminum profile selection, and signal polarity or wiring faults.
  • Works with overseas contractors, designers and purchasing teams on voltage, wattage, cutting intervals, IP ratings and control compatibility, reducing rework from sampling to bulk installation.
Recipient of the China Lighting & Lamps Industry Linear Lighting Application Innovation Award and the LED CHINA Commercial Linear Lighting Solution Excellence Award.

Focused on bringing real engineering parameters and field troubleshooting experience into every LED strip technical guide.

Click To Action

Get a free consultation with us!