Greenhouse Strip Lighting: Humidity, Chemicals and Where the Driver Lives
- 2026-11-23 16:44
- /
- Alan
A greenhouse runs at 80–95% relative humidity for weeks, and often uses sulphur vaporisers. That is a hostile environment for any electronics that are not sealed and placed deliberately.
A propagation house added strip lighting along the bench edges. The strip survived the first season; four drivers failed in the same period. The drivers had been mounted on the bench frame, inside the growing zone, at the same humidity as the plants.
Why the driver fails first
Strip with a proper extrusion can tolerate condensing humidity. A constant-voltage driver has ventilation slots, a fan and a case that breathes. Moisture enters, condenses on the board when the driver cools at night, and corrosion starts on the control side where voltages are low and clearances are small.
Sulphur compounds from vaporisers attack silver and copper even at low concentrations. A driver that would last ten years in an office can fail in two seasons in a treated greenhouse.
Where to put things
- Drivers outside the growing zone, in a service corridor or plant room at normal humidity.
- If they must be inside, use IP65 or IP67 drivers with sealed cases and no fan.
- Run the DC feeder into the house through a gland, not an open slot.
- Keep drivers off the floor and off the bench frame where irrigation water reaches.
The feeder run from an external driver to the strip has voltage drop, which is the trade-off. At 24V and 20 m, use 2.5 mm² and calculate the loss before assuming it is acceptable. At 48V the same cable carries half the current and the run becomes practical.
Strip selection
IP67 with a full extrusion and sealed ends is the baseline. Silicone coating alone is not enough where water condenses on the surface nightly. Avoid joints inside the growing zone; bring each section back to a sealed connector block outside the wet area.
Chemical compatibility matters too. Some coatings discolour or embrittle with sulphur or chlorine exposure. Ask for the coating material and test a sample in the house for a season before committing a full bench.
Condensation on the strip
Water on the diffuser costs a few percent of output and is unavoidable in some houses. Water inside the extrusion is a fault. Check the ends and the cable entries at every crop turnaround, which is the natural maintenance interval.
What we changed
On the propagation house we moved all drivers to a service corridor, ran 48V DC to the benches, and used IP67 strip with sealed connectors at each bench end. Driver failures stopped. The strip needed one end-cap replacement in the second season, which is a maintenance item rather than a design failure.
Keep a simple log of failures by position. In a house with dozens of benches, a pattern usually points to a wet corner or a dripping joint rather than to the product.