Joint Resistance: The Connector That Costs Two Volts at 30 Metres
- 2026-11-23 16:32
- /
- Alan
Every joint is a resistor in series with the strip. At 8.75 A, 0.2 ohm costs 1.75V — the same as adding several metres of board. And it gets hotter every year.
On the 30 m retail cove we measured a 1.9V step across a single solderless connector at 12 m. The strip before it read 22.9V, after it 21.0V. The connector looked fine. It clipped on with a positive click. It was simply a poor contact.
Why contact resistance grows
Most solderless connectors rely on a metal prong biting into a pad. The initial contact may be a few milliohms. Over time, thermal cycling, dust, silicone residue and slight movement increase it. In a warm cove the joint runs hotter than the strip, which accelerates oxidation, which raises resistance further. The process is slow and then sudden.
Cheap connectors with plated steel contacts are worse than copper alloy. Connectors sized for 5A used on an 8A run are worse again.
How to measure a joint
With the strip lit, put one probe on the pad before the joint and one after it. The difference is the voltage across the joint. Below 0.1V is acceptable on a 24V run; 0.3V is worth replacing; 0.5V or more is a defect.
Then touch it. A joint that is noticeably warmer than the strip 100 mm away is dissipating power it should not. On the 1.9V joint the plastic was soft after 30 minutes.
Fixes, in order of preference
- Replace with a correctly rated connector for the strip width and current, then re-measure.
- Solder the joint where the strip is accessible and the pads allow it. A proper solder joint is typically a few milliohms and does not move.
- Move the joint to a service point if it must remain a connector, so future replacement is easy.
- Split the load so less current passes through the joint; a joint carrying 4A dissipates a quarter of the power of one carrying 8A.
Do not simply tighten or re-seat a connector and call it fixed. Re-seating can restore contact for a month and then fail again. Measure after the fix and record the value.
Joint count is a design variable
A 30 m run made from six 5 m reels has five joints. At 0.1 ohm each that is 0.5 ohm in the current path, costing roughly 4V distributed — more than the board itself. Reducing joint count, or feeding each segment in parallel, removes that loss entirely.
On commercial work we prefer four 8 m segments with home runs over one 32 m chain of reels, even where the chain looks neater. Fewer joints, less voltage loss, easier fault isolation.
Connectors in damp or dusty coves
IP-rated connectors help with moisture but do not guarantee low contact resistance. Gel-filled or sealed connectors are better in humid ceilings, but the contact area still needs to be clean at assembly. Silicone grease on the contacts is not a substitute for correct crimping or clamping.
If the cove is above a kitchen or in a coastal building, inspect joints at the first service interval rather than waiting for a dim-tail complaint. Our strip connector range lists current ratings, and our COB strips show the W/m that sets the current through each joint.