Keeping Mains and Low-Voltage Wiring Separate Inside One Cabinet
- 2026-11-26 18:02
- /
- Alan
Inside one cabinet the mains feed to the driver and the SELV feed to the strip should be routed apart, kept in distinct compartments, and terminated away from each other.
A fitted wardrobe and kitchen cabinet often pack the driver, receiver and several cable runs into a small plinth or back panel. The line-voltage feed and the low-voltage strip conductors can end up bundled together, which is a separation and interference risk.
Why separation matters
The driver input is mains voltage; the strip side is SELV. Keeping them apart avoids contact risk and reduces coupling that can cause audible noise, sensor interference or dimming glitches. Bundled conductors also make future servicing harder to trace.
Inside a timber cabinet there is usually room to run the two cable types in opposite sides of the cavity or through separate channels. A little planning at the cabling stage prevents a service technician from guessing which lead is which.
Routing practice
- Run mains and SELV conductors separately rather than parallel alongside each other for long stretches.
- Keep the line feed to one side of the driver terminal block and the SELV output to the other.
- Avoid running the low-voltage strip cable beside the mains lead through a shared clip or hole.
- Label each cable so later service can tell them apart at a glance.
Terminations and compartments
Where the cabinet has compartments or a terminal compartment, keep the mains entry and the strip terminations in different sections. A shared terminal block that mixes line and SELV conductors should be split or replaced.
Check that no cable strain pulls the mains terminal loose; the feed should be anchored so its weight sits on the fixing, not on the screw connection. Leave the two sides of the block visibly distinct.
Interference check at commissioning
Switch the system through its dimming range and watch the strip for flicker, hum or sensor misfires. If a glitch appears only when another cabinet circuit is on, the cable routing or separation is the likely cause.
A clean separation plan at the design stage avoids opening the finished cabinet later to re-separate two bundles that were tied together on site. Walk the cavity once before the back panel goes on to confirm the routing, and check that no mains lead passes within the SELV zone at the driver terminals.
Installation Checklist
- Confirm the strip voltage, per-metre load and total run length before sizing the supply or controller.
- Check the mounting position for moisture, heat, clearance and any obstruction before fixing the run.
- Test the sensor, receiver or controller in the finished position, with doors and panels closed.
- Keep drivers, joints and receivers reachable so the run can be serviced without reopening the finish.
Recommended Products
For this detail, the following Arraystarled products are listed in our current catalogue and can be matched to the run after the supply, enclosure and control requirements are confirmed:
- ART-1715B P20 Linear LED Aluminum Channel Profile
- ART-Square19 Corner LED Aluminum Channel Profile
- ART-1310 Asymmetric Aluminum LED Profile Channel
Aluminium profiles and channels keep the strip and its visible wiring organised; the mains-to-SELV separation at the driver terminal block remains the electrician's responsibility.
Talk to our application team with your strip length, voltage and ambient condition; we will match the supply, controller or sensor to the actual run rather than a generic rule.