Thermal Imaging a Warm Feeder: Reading the Hot Spot Before It Fails
- 2026-11-23 16:32
- /
- Alan
Everything resistive gets hot. The useful question is which part is hottest. A thermal image answers it in thirty seconds and saves an hour of probing.
On long 24V runs we now take a thermal image at handover. It is faster than touching joints one by one, and it leaves a record. On the 30 m cove job the image showed three hot spots: the feeder where it left the driver, one connector at 12 m, and the strip pad where the feeder landed.
What a normal image looks like
A healthy 7 W/m strip at 24V shows a gentle, even temperature along its length, a few degrees above ambient, with no isolated bright spots. The feeder is close to ambient. Joints are within a degree or two of the strip beside them.
A problem shows as a localized bright patch with a sharp edge. The absolute temperature matters less than the contrast: a joint 12°C hotter than the strip 100 mm away is dissipating power and will degrade.
Reading the three common patterns
| Pattern | Likely cause | Fix |
|---|---|---|
| Whole feeder uniformly warm | Undersized conductor at high current | Increase gauge or shorten the DC path |
| Bright spot at a joint | Contact resistance | Replace or solder the joint |
| Hot patch where the tail meets the strip | Solder or crimp resistance, thin tail | Re-terminate with correct tail size |
How to take a useful image
- Run the load for at least 30 minutes. Cold joints hide.
- Set the camera span manually; auto-span will make a 3°C difference look dramatic or invisible depending on the frame.
- Shoot perpendicular to the surface. Reflections from shiny aluminum read as false hot spots.
- Include the driver, the feeder, the first joint and the last metre in one frame if possible.
- Record ambient temperature and emissivity setting with the image.
What we changed on the 30 m job
The feeder was 0.75 mm² over 9 m, carrying 8.75 A. The image showed it 14°C above ambient along its whole length. We replaced it with 2.5 mm² and the feeder temperature fell to 4°C above ambient. The 12 m connector was 11°C above the strip and was replaced under warranty; the pad termination was re-soldered.
Far-end voltage rose from 21.2V to 23.4V without changing the driver. The thermal image did not just find a fault; it pointed to the three parts that were costing voltage.
When not to rely on it
Thermal imaging shows temperature, not voltage. A joint can be electrically poor but thermally mild if the current through it is low. Use the image to prioritize, then measure voltage across the suspect joint to confirm.
It also cannot see inside a sealed driver or a gel-filled connector. Those need electrical measurement and, if suspect, replacement.
For handover files we include one overview image per zone and one close-up per joint group. It takes ten minutes per site and settles most call-backs before they happen. Our connector range shows the current ratings that set what a joint should carry.