The Thirty-Minute Full-Load Test Before You Hand Over a Cove
- 2026-11-23 16:33
- /
- Alan
Cold measurements flatter every installation. Copper resistance rises with temperature, connectors expand, drivers heat up and current creeps. Thirty minutes at full output is the minimum that produces honest numbers.
We started doing this after a handover where everything read correctly at switch-on and the client called back a week later about a dim tail. The tail had been marginal cold and failed warm. The difference was 0.6V and one loose connector. Since then it has been a fixed step on every commercial job, written into the method statement rather than left to the installer's discretion.
What the test is for
It is not a soak test and not a burn-in. It is a steady-state check of the electrical and thermal conditions the installation will actually live in. You are looking for drift: voltage falling, joints heating, drivers getting hotter than their rating allows.
Sequence
- Switch on all zones at 100% and set every dimmer to full.
- Record ambient temperature and the time.
- At 2 minutes, take baseline voltage at driver, strip start, midpoint and end.
- At 30 minutes, repeat all four readings plus case temperature at each driver and a touch check on every accessible joint.
- Photograph the thermal camera view if you have one.
- Log the values in the handover sheet and sign it.
What the numbers should look like
| Check | Acceptable | Investigate |
|---|---|---|
| Far-end drop vs driver | Under 5% | Over 10% |
| Drift cold to warm | Under 0.3V | Over 0.5V |
| Joint rise above strip | Under 5°C | Over 10°C |
| Driver case temperature | Under 60°C in a cove | Over 70°C |
Things that only show up warm
A connector that reads 0.05 ohm cold can read 0.2 ohm warm if the contact is marginal. A driver at 80% load cold can exceed its derated capacity once the void heats up. A strip on a cold aluminum channel can sag against a tight clip after thermal expansion.
None of these appear in a two-minute check. All of them appear in a client complaint three weeks later.
We also use the thirty minutes for the non-electrical items that are easier to fix now than later: diffuser fit, clip spacing after thermal expansion, and whether the strip has lifted off its mounting surface near the warm end of the run.
What to do when a reading fails
Do not adjust the driver upward to compensate. Fix the cause: replace the joint, resize the feeder, add an injection point, or split the zone. Then repeat the thirty-minute test and record the new numbers.
If the installation cannot be corrected before handover, document the deviation and the temporary measure in writing. A signed sheet with a known limitation is better than an undocumented compromise.
Our COB strip data gives the W/m used to predict these numbers at design stage, and the driver range lists derating curves for the ambient you measure.